Customization: | Available |
---|---|
Certification: | RoHS, CE, ISO, CCC |
Shape: | GT |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Value | Unit |
BVDSS @Tj,max | 850 | V |
ID | 6.6 | A |
RDS(on), max | 0.85 | Ω |
Qg, Typ | 13.7 | nC |
Symbol | Parameter | Value | Unit |
VDSS | Drain-Source Voltage | 800 | V |
VGS | Gate-Source Voltage | ±20 | V |
ID |
Drain Current - Continuous (TC = 25ºC) | 6.6 * | A |
ID |
Drain Current - Continuous (TC = 100ºC) | 4.2 * | A |
IDM1) | Drain Current - Pulsed | 19.8 * | A |
EAS2) | Single Pulsed Avalanche Energy | 56 | mJ |
IAR | Avalanche Current | 1.15 | A |
dv/dt | MOSFET dv/dt ruggedness, VDS=0.400V | 50 | V/ns |
dv/dt | Reverse diode dv/dt, VDS=0.400V, IDS≤ID | 15 | V/ns |
PD | Power Dissipation (TC = 25ºC) | 27 | W |
TJ, TSTG | Operating and Storage Temperature Range | -55 to +150 | ºC |
Symbol | Parameter | Value | Unit |
RθJC | Thermal Resistance, Junction-to-Case, Max. | 4.57 | ºC/W |
RθJA | Thermal Resistance, Junction-to-Ambient , Max. | 80 | ºC/W |
Symbol | Parameter | Test Conditions | Min | Typ | Max | Unit | |
On Characteristics | |||||||
VGS | Gate Threshold Voltage | VDS = VGS, ID = 220 μA | 2.0 | - | 4.0 | V | |
RDS(ON) | Static Drain-Source On-Resistance | VGS = 10 V, ID = 1.6 A | - | 0.74 | 0.85 | Ω | |
Off Characteristics | |||||||
BVDSS | Drain-Source Breakdown Voltage | VGS = 0 V, ID = 1mA | 800 | - | - | V | |
IDSS |
Zero Gate Voltage Drain Current |
VDS = 800 V, VGS = 0 | - | - | 1 | μA | |
VDS = 800 V, TC = 150ºC | - | - | 100 | μA | |||
IGSS | Gate-Body Leakage Current | VGS = ±20 V, VDS = 0 V | - | - | ±1 | μA | |
Dynamic Characteristics | |||||||
Ciss | Input Capacitance | VDS = 500 V, VGS = 0 V, f = 1.0 MHz |
- | 635 | - | pF | |
Coss | Output Capacitance | - | 14.6 | - | pF | ||
Crss | Reverse Transfer Capacitance | - | 2.5 | - | pF | ||
Switching Characteristics |
|||||||
td(on) | Turn-On Time | VDS = 400 V, ID = 2.8 A, RG = 25 Ω (Note 3,4) |
- | 23 | - | ns | |
tr | Turn-On Rise Time | - | 18 | - | ns | ||
td(off) | Turn-Off Delay Time | - | 74 | - | ns | ||
tf | Turn-Off Fall Time | - | 17 | - | ns | ||
Qg( | Total Gate Charge | VDS = 640 V, ID = 2.8 A, VGS = 10 V (Note 3,4) |
- | 13.7 | - | nC | |
Qgs | Gate-Source Charge | - | 2.9 | - | nC | ||
Qgd | Gate-Drain Charge | - | 4.2 | - | nC | ||
Drain-Source Diode Characteristics and Maximum Ratings |
|||||||
IS | Maximum Continuous Drain-Source Diode Forward Current | - | - | 6.6 | A | ||
ISM | Maximum Pulsed Drain-Source Diode Forward Current | - | - | 19.8 | A | ||
VSD | Drain-Source Diode Forward Voltage | VGS = 0 V, IS = 2.8 A | - | - | 1.3 | V | |
trr | Reverse Recovery Time | VR = 400 V, IF = 2.8 A diF/dt = 100 A/μs | - | 170 | - | ns | |
Qrr | Reverse Recovery Charge | - | 1.1 | - | μC |
Q1:What service do you have?
We provide turnkey solution including RD, PCB fabrication, SMT, testing and other value-added service.
Q2:What are the main products of your PCB/PCBA services?
Our PCB / PCBA services are mainly for the industries including Medical, Automotive, Energy, Metering / Measurements, Consumer Electronics.
Q3:Can we inspect quality during production?
Yes, we are open and transparent on each production process with nothing to hide. We welcome customer inspect our production process and check in house.
Q4:How can we ensure our information should not let third party to see our design?
We are willing to sign NDA effect by customer side local law and promising to keep customers data in high confidential level.
Q5:What files required to get quotation from you?
For PCB quotation, please provide the Gerber data / files and indication of related technical requirements as well as any special requirement if you have.
For PCBA quotation, please provide Gerber data / files and also BOM (bill of materials), and if you need us to do function test, please also provide the test instruction/procedure.
Q6:What is standard delivery term?
Delivery terms of EXW, FCA, FOB, DDU etc. are all available based on each quote.
Q7:How long does it take for PCB quote?
Normally 12 hours to 48 hours as soon as receive internal engineer evaluate confirmation.
Q8:Do you have any minimum order quantity (MOQ) requirement?
No, we do not have MOQ requirement, we can support your projects starting from prototypes to mass productions.